Category: News

  • Security Issue 20101222-0700 Vulnerability Note

    SQL Authentication Vulnerability IntegraXor 3.6.4000.5 is now added with Read and Write level column to database table which allows user to configure security level for individual database entry. Now only user with security level higher than or equal to the read level can browse for trend and alarm data, and user with security level higher […]

  • SCADA Vulnerability/Security Issues

    Crossing 2011 seems to be quite challenging for IntegraXor team in handling security issues. However we are very glad that several security researcher are helping us in finding security vulnerability and even help us to verify the patched release when the loophole is fixed. We wish to thank them and also Kevin, Kathy & Bryan […]

  • IntegraXor 3.6 SCADA Security Issue 20101222-0323 Vulnerability Note

    Further to our earlier security note about buffer over flow, it seems the publication has drawn more interest from security researchers, Industrial Control System Cyber Emergency Team (ICS-CERT) has again contacted us on Directory Traversal attack. This vulnerability can be exploit by attacker to download files from the SCADA server. However, attack by deleting file […]

  • IntegraXor 3.6.4000.0 dated 17 Dec 2010 Change Log

    + Added most waited innovative report module, allowing one time layout configuration for both display and printout at one go. + Added setSql() and getSql() for more convenient database interactions. + Added table import/export function for faster data entry work. + Added OPC server into standard release. ^ PE save tables based on proper dependency […]

  • IntegraXor 3.5 SCADA Security Issue 20101006-0109 Vulnerability Note

    Earlier this October, the Industrial Control System Cyber Emergency Team (ICS-CERT), managed and operated by the United States Department of Homeland Security Control Systems Security Program, has received a report from an independent security researcher of a vulnerability in IntegraXor. ICS-CERT works in coordination with US-CERT, with a focus on control systems cyber security. Below […]

  • You can now spray with Inkscape 0.48

    It has been quite a while that we hold IntegraXor users to work on Inkscape 0.46. Finally our SAGE developer Teow has managed to spend some times to migrate SAGE to the latest version of Inkscape 0.48. Spray is not the only feature that added into Inkscape 0.48 release, there are a lot more to […]

  • IntegraXor 3.5.3900.10 dated 08 Oct 2010 Change Log

    Updated front-end Alarm Viewer for faster loading over slow Internet connection. Updated minor section of documentation. Fixed stability issue for specific add-in module.

  • IntegraXor 3.5.3900.5 dated 15 Sep 2010 Change Log

    Added find and replace. Added always on top option. Added email output support, which allows alarm to be sent via email. Added Modbus driver string data type support and fixed ASCII mode bug. Added interval timer support, configured via Timer table. Added tooltip help for each column header in all table grid. Added configuration for […]